Climate test cabinet WKS 3-1000/70/5

Climate Test Cabinet with increased change rates - Stress Screening System Weiss Type WKS 3-1000/70/5 - Highly accurate temperature and climate conditions are achieved by an adaptive control system that continuously optimizes the control behavior.

Stress Screening System Weiss, WKS3-1000-70-5 climate chamber

Type: WKS 3-1000/70/5 
Test space contents (Litre): 990

Test chamber material
stainless steel, 1,4301, surface III D polished

Material of test space floor
1,4404, matt surface

Test space dimensions 
Height approx. (mm): 950
Width approx. (mm): 1100
Width Between - shelfs supports (mm): 1060
Depth approx. (mm): 950

Outside dimensions 
Height approx. (mm): 2005 
Width approx. (mm): 1300
Depth approx. (mm): 1925

Condenser: water-cooled
Chamber weight in kg (approx.): 1100 

Performance data for temperature tests 
Maximum temperature (°C): +180
Minimum temperature (°C): -72, discontinuously

Temperature changing rate cooling (K/min): 6.0
Temperature changing rate heating (K/min): 8.0

Temperature constancy in time (K): ±0.1 to ±0.5
Temperature homogeneity in space (K): ±0.5 to ±.2.0

Maximum heat compesation (W): 5000
Calibration values (°C): +23 and +80


Performance data for climate tests according to IEC 60068-3-6
Maximum temperature (°C): +95
Minimum temperature (°C): +10 

Humidity deviation in steady state,
depending on the climatic value (K): ±0.1 to ±3, in time

Temperature deviation, in time, in steady
state, depending on the temperature (K): ±0.1 to ±0.3

Temperature homogeneity in space (K): ±0.5 to ±1.0

Dew point temperature range: (°C): -3 to +4 ... +94
Humidity range (% r.h.): 10 – 98

Humidity water consumption, for every 24h (Litre): 2

Maximum heat compensation (W): 500
Calibration values (°C/%r.h.): 23/50, 95/50

Test standards for climate test cabinets with fast temperature change rates

Cold 
IEC 60068-2-1, Test A 
IEC 60721-4
ISO 16750-4, Low temperature
ETSI EN 300019-2-4, Test Ab/Ad
MIL-STD-810 G, Meth. 507.5
MIL-E-5272, part 4.2
JESD22-A119

Heat 
IEC 60068-2-2, Test B
IEC 60721-4
ISO 16750-4, High temperature
ETSI EN 300019-2-4, Test Bb/Bd
MIL-STD-202 G, Meth. 108A
MIL-STD-810 G, Meth. 501.5
MIL-STD-883 J, Meth. 1008.2
MIL-E-5272, part 4.1
JESD22-A103D

Constant climates 
IEC 60068-2-67
IEC 60068-2-78
IEC 60721-4
ISO 16750-4, Damp heat steady
ETSI EN 300019-2-4, Test Cab
MIL-STD-202 G, Meth. 103B
JESD22-A101C

Alternating temperatures 
IEC 60068-2-14, Test Nb
ISO 16750-4, Temp. steps
ISO 16750-4, Temp. cycling
ETSI EN 300019-2-4, test Nb.
MIL-STD-331 C. Test c6
JESD22-A105C

Alternating climates 
IEC 60068-2-30, Test Db, Var. 1
IEC 60068-2-30, Test Db, Var. 2
IEC 60068-2-38
ISO 16750-4, Damp heat cyclic
ISO 16750-4, Tem/humid, cyclic
ETSI EN 300019-2-4, Test Db
VG 95210, page 7, Meth. 106C
MIL-STD-202, Meth. 106D
MIL-STD-331 C, Test C1
MIL-STD-750-1, Change 3
MIL-STD-810 G, Meth. 507.5
MIL-STD-883 J, Meth. 1004.7
MIL-E-5272, part 4.4
JESD22-A100D

The temperature values specified in the standards (inspection levels) are limited by the highest and lowest test space temperature. The choice of the adequate test system depends on the temperature change rates during alternating tests. The requirements are met if the test system capacity is high enough to compensate the influence of the specimen and its heat dissipation in the relevant capacity range. Certain test standards with contaminated specimen require the optional cleaning device (mat. no. 64609956) to ensure the required water quality.

Please contact us to test the feasibility with your test specimen.